CGL-BU Use:
It can remove impurities from oil, absorb water, avoid acidity of oil from going higher and keep lubricating nature of oil. It uses filtering theory of bypass structure. Oil flow through oil-pressure pump and shunt some amount of oil flowing into CGL oil cleaner to filter precisely by high pressure and special flow adjustment, and then flow back to oil tank. It makes good use of connection and unloading power, so it does not need adding electricity consumption. Only need to replace filtering element, other time do not need to maintain.
Technical Parameter List
| Model |
CGL-BU32 |
CGL-BU50 |
CGL-BU100 |
| Suitable Oil Kinds |
Hydraulic oil,lubricating oil...etc |
| Filterin Precision |
Reach NASS 5-7 grade(one pass) |
| Suitable Pressure Range |
10-210kgf/cm2 |
| Flow(L/min) |
1.0 |
1.5 |
2.0 |
| Oil Temperature Range |
0-80℃ |
| Oil Viscosity Range |
9-180cSt |
| Inlet And Outlet Size of Oil Pipe |
IN.RC 1/4,OUT.G3/8 |
| Pressure Meter |
¢40 including oil pressure meter 0 - 10kgf/cm2 |
| Weight(kg) |
¢40 including oil pressure meter 0 - 10kgf/cm |
| Suitable Capacity of Oil Tank |
No more than 300L |
No more than 500L |
No more than 1000L |
| Size mm(L*W*H) |
140*140*300 |
220*220*310 |
300*300*330 |
Dimension and weight will be changed with the changing of the technical specification.
CGL-SE Use:
It can remove impurities from oil, absorb water, avoid acidity of oil from going higher and keep lubricating nature of oil. It has power and is suitable for low-pressure structure. The installation is easy and the oil route of machine will not be affected. It also has special circuit connection. Its three phase supper supply does not need procedure of changing connection. There is rough filtering net structure and transparent watching cup, so it is easy to clean and can protect oil pump and prolong lifespan of machine greatly.
Technical Parameter List
| Model |
CGL-SE32 |
CGL-SE100 |
| Suitable Oil Kinds |
Hydraulic oil,lubricating oil...etc |
| Filtering Precision |
Reach NASS 5-7 grade(one pass) |
| Flow(L/min) |
1.5 |
2.5 |
| Oil Temperature Range |
0-80℃ |
| Oil Viscosity Range |
9-180cSt |
| Pressure Meter |
¢40 including oil pressure meter 0-10kgf/cm2 |
| Inlet and Outlet Size of Oil Pipe |
¢10 |
| Size mm (L*W*H) |
350*250*470 |
350*250*470 |
| Weight(kg) |
14.5kg |
17.5kg |
| Motor |
Single phase 1/4HP |
| Suitable Capacity of Oil Tank |
No more than 300L |
No more than 1000L |
Dimension and weight will be changed with the changing of the technical specification.